Zhongshan Broad Ocean Motor Replacements Compared by Fit
Choose a Zhongshan Broad-Ocean motor replacement by matching the original part number and application, since these options cover different fan, blower and inducer jobs. If you need a single universal motor, these are not interchangeable; verify the motor type and part number before ordering.
We earn a commission if you buy through links on this page. As an Amazon Associate I earn from qualifying purchases. Products are compared on manufacturer specifications, not hands-on testing.
- For RV AC condenser fan: D1092 RV AC Condenser Fan Motor – Its compatibility list includes Broad-Ocean Y6L457D01L and Coleman Mach 6000 and 8000 Series units.
- For Y4L241A58 inducer: Y4L241A58 OEM Furnace Inducer Motor – This two-speed, 115V inducer motor is identified for Broad-Ocean Y4L241A58.
- For Y7L623E21 blower: Y4L241A58 Inducer Motor with Harness – The blower motor is 1/2 HP, 115V and four-speed.
- For Y4L241A58 furnace: Y7L623E21 1/2 HP Blower Motor – This option includes a wiring harness, gasket and six mounting screws.
| Product | Best for | Motor type | Voltage | Speed | Shop |
|---|---|---|---|---|---|
| D1092 RV AC Condenser Fan Motor | RV AC condenser fan | Condenser fan | 115V | 2 speeds | Check Price on Amazon |
| Y4L241A58 OEM Furnace Inducer Motor | Furnace inducer | Furnace inducer | 115V | 2 speeds | Check Price on Amazon |
| Y7L623E21 1/2 HP Blower Motor | Four-speed blower | Blower motor | 115V | 4 speeds | Check Price on Amazon |
| Y4L241A58 Inducer Motor with Harness | Harness included | Furnace inducer | — | — | Check Price on Amazon |
| Y7S623C835L Condenser Fan Motor | 208–230V condenser fan | Condenser fan | 208–230V | — | Check Price on Amazon |
Zhongshan Broad Ocean Motor Replacements
Match the motor type and original part number to your system before comparing electrical and physical specifications.
D1092 RV AC Condenser Fan Motor

This is the only option here that names an RV air-conditioner condenser fan application, and it lists compatibility with Broad-Ocean Y6L457D01L. The motor is 1/3 HP, 3.4 A and 60 Hz, with 1675/1080 RPM speeds; a 7.5 μF/370V capacitor is included. Its shaft dimensions are 7-15/16 inches by 1/2 inch by 3-9/16 inches, and the body diameter is 5-5/8 inches. It suits compatible Coleman Mach 6000 and 8000 Series units. Its RV AC fit makes it the wrong type for a furnace inducer or indoor blower.
Bottom line: Choose this for a compatible RV AC condenser fan when the original part number and shaft dimensions match.
Y4L241A58 OEM Furnace Inducer Motor

This option is the straightforward Y4L241A58 furnace inducer choice, with two speeds, 115 volts and 3030 RPM. An inducer motor serves the furnace exhaust-draft function, so it is not a substitute for a blower motor that moves heated air through ducts or an AC condenser fan motor. The name identifies it as an OEM-upgraded replacement for Broad-Ocean/Zhongshan. Choose it when Y4L241A58 is the original part number and the furnace application matches. The maker does not give horsepower or mounting dimensions, so compare those against the original motor if they determine fit.
Bottom line: Choose this for a furnace requiring the Y4L241A58 inducer motor.
Y7L623E21 1/2 HP Blower Motor

This option stands apart as the four-speed indoor blower motor, identified as replacement for Zhongshan Broad-Ocean 0131F00022 and Y7L623E21. It is rated 1/2 HP, 115 volts and 1130 RPM. The horsepower, voltage and speed count are useful screening values, but they do not alone establish mechanical or electrical compatibility: confirm that the original model and wiring arrangement match. The product is for a blower application, not a furnace exhaust inducer or an outdoor condenser fan. Choose it when replacing the matching Y7L623E21 blower assembly motor.
Bottom line: Choose this for a matching 0131F00022/Y7L623E21 four-speed blower application.
Y4L241A58 Inducer Motor with Harness

This Y4L241A58 replacement differs from the other inducer option by listing a wiring harness, gasket and six mounting screws in the package. It is described for compatible Carrier, Heil and ICP furnace systems and names Broad-Ocean Y4L241A58 as its replacement reference. Confirm the original part number and furnace fit before choosing it; do not assume that a matching number alone confirms every mounting or wiring detail.
Bottom line: Choose this when the Y4L241A58 reference matches and the included harness and gasket suit the replacement job.
Y7S623C835L Condenser Fan Motor

This is the 208–230V condenser fan option, separate from the 115V RV AC motor. It names Broad-Ocean Y7S623C835L and cross-references several HC39 part numbers; its rating is 1/4 HP. The application is a compatible Zhongshan Broad-Ocean fan motor. Use the exact original part number and voltage as the first checks, since a condenser fan motor’s voltage class and mounting fit must match the system.
Bottom line: Choose this for a matching 208–230V Y7S623C835L condenser fan application.
How to choose a Broad-Ocean motor replacement
Start with the complete original motor number, then check the motor’s job: inducer, indoor blower or condenser fan. These types do different work and are not interchangeable merely because they share a brand or voltage. Next compare voltage, speed count, horsepower when supplied, and shaft or mounting dimensions. A 115V motor is not a substitute for a 208–230V motor unless the equipment is designed for that electrical supply. For a measurable rule, reject any candidate whose voltage does not match the original motor’s voltage class. Cross-reference numbers can help narrow candidates, but verify the equipment model and physical fit as well.
For HVAC motor work, disconnect power at the breaker and verify that the circuit is de-energized before handling wiring. Capacitors can retain a charge after power is off; use a qualified technician if you cannot safely discharge and verify components.
How inducer, blower and condenser motors differ
An inducer motor supports furnace exhaust draft, an indoor blower moves conditioned air through ducts, and a condenser fan moves air across the outdoor coil. Those duties require the right motor type and compatible mounting, rotation and electrical characteristics. The table gives a first-pass distinction using the options here; it is not a universal motor-sizing chart.
| Application | What it does | Selection check |
|---|---|---|
| Furnace inducer | Moves exhaust air | Match inducer part number and furnace |
| Indoor blower | Moves air through ducts | Match blower model, speeds and wiring |
| Condenser fan | Moves air across outdoor coil | Match voltage, shaft and rotation |
Do not choose a motor by horsepower or voltage alone: physical dimensions and control connections can also prevent a replacement from fitting.
Which motor specifications matter for fit
Part number, voltage and motor type are the first three checks; shaft dimensions and rotation matter especially for fan motors. For example, a shaft length or diameter mismatch can prevent the fan hub from seating correctly, even if the electrical rating looks similar. Compare the original motor’s label and measurements with the replacement’s specifications, including speed count, RPM and capacitor rating where applicable. Cross-reference numbers can span related equipment, so confirm the precise system model rather than relying on a broad family name. For the RV fan motor, the shaft and body dimensions offer concrete fit checks; for other options, use the original motor dimensions to verify clearance and mounting.
Safe motor replacement and common mistakes
Disconnect and verify power before working on HVAC wiring, and treat capacitors as potentially charged after shutdown. Motor replacement can involve line voltage, moving fan blades and system-specific wiring, so use a qualified HVAC technician if you are not trained to isolate and verify the circuit. A frequent mistake is swapping an inducer, blower or condenser motor because the voltage appears to match; those applications have different jobs and mounting requirements. Another is assuming that a cross-reference guarantees compatible rotation, shaft size and wiring. Confirm the full part number, voltage class, electrical connections and physical dimensions before installation, and make sure guards and panels are restored before operating the equipment.
Frequently Asked Questions
Can I replace a 115V motor with a 208–230V motor?
No, not unless the equipment is designed for the replacement motor’s voltage class. Match the motor label and equipment electrical supply before selecting a replacement.
What does a furnace inducer motor do?
A furnace inducer moves exhaust air to support the furnace’s draft. It is different from the indoor blower, which moves heated air through ducts.
Why do fan motor shaft dimensions matter?
The shaft must fit the fan hub and mounting arrangement. Compare shaft diameter and length with the original; a mismatch can prevent proper seating.
Should I replace a motor capacitor with the motor?
Use the capacitor rating required by the motor and equipment, measured in microfarads and voltage. Do not substitute a different rating based only on physical fit.
Is it safe to handle an HVAC motor after switching power off?
Not until the circuit is verified de-energized; a capacitor may retain charge after shutdown. If you cannot safely verify and discharge components, have a qualified technician do the work.