XR Storm Responder 6250 Conversion Kit is the best choice when its Briggs XR Storm Responder 6250 generator fit and 9–13.8-inch water-column inlet requirement match your setup. These kits can serve different engines and fuel systems, so choose another option if your generator model or regulated fuel supply does not match.
We earn a commission if you buy through links on this page. As an Amazon Associate I earn from qualifying purchases. Products are compared on manufacturer specifications, not hands-on testing.
- Best overall: XR Storm Responder 6250 Conversion Kit – Fits the Briggs XR Storm Responder 6250 and gives a 9–13.8-inch water-column inlet-pressure range.
- Best for Genpower 6000: Genpower 6000 257417 Impco Kit – A complete tri-fuel kit for Briggs Genpower 6000 257417, designed for an already regulated system.
- Best for model 030728: 030728 Tri-Fuel Conversion Carburetor – A tri-fuel conversion carburetor identified for Briggs & Stratton generator 030728.
- Best for 402707/422707: 402707/422707 Impco Low-Pressure Kit – A complete tri-fuel kit identified for Briggs & Stratton engine models 402707 and 422707.
| Product | Best for | Compatible model | Fuel options | Supply setup | Shop |
|---|---|---|---|---|---|
| XR Storm Responder 6250 Conversion Kit | XR Storm Responder | XR Storm Responder 6250 | Gasoline, propane, natural gas | 9–13.8 in. wc inlet | Check Price on Amazon |
| Genpower 6000 257417 Impco Kit | Genpower 6000 | Briggs Genpower 6000 257417 | Gasoline, propane, natural gas | Already regulated system | Check Price on Amazon |
| 030728 Tri-Fuel Conversion Carburetor | Generator 030728 | Briggs generator 030728 | Propane tri-fuel | Carburetor conversion | Check Price on Amazon |
| Briggs and Stratton Propane/Natural Gas Kit | General conversion | Briggs and Stratton | Propane, natural gas | — | Check Price on Amazon |
| 402707/422707 Impco Low-Pressure Kit | 402707/422707 engines | Briggs Stratton 402707/422707 | Gasoline, propane, natural gas | Already regulated system | Check Price on Amazon |
Briggs and Stratton Propane Conversion Kits
Match the kit to the generator or engine model first, then confirm the fuel supply and installation requirements.
XR Storm Responder 6250 Conversion Kit

Unlike the other kits here, this option gives a specific inlet-pressure range: 9–13.8 inches of water column. It is made for the Briggs XR Storm Responder 6250 generator and supports gasoline, low-pressure propane, and low-pressure natural gas. The alternative-fuel hose requires case modification, so this is a better fit for someone prepared to make that change. The fuel supply must meet the pressure range; a mismatch can make this kit unsuitable even when the generator model matches.
Bottom line: Choose this if you have the specified generator and can provide the required inlet pressure.
Genpower 6000 257417 Impco Kit

This complete tri-fuel kit is specifically matched to the Briggs Genpower 6000 257417, unlike options tied to a different generator or engine model. It supports gasoline, low-pressure propane, and low-pressure natural gas, and is designed to connect to a system that is already regulated. That supply requirement is the main limitation: buyers without a regulated fuel system should not assume the kit includes everything needed to create one. Confirm the generator identification before selecting it.
Bottom line: Pick this for a Genpower 6000 257417 with an already regulated fuel system.
030728 Tri-Fuel Conversion Carburetor

This is the carburetor-style option, identified for Briggs & Stratton generator 030728 rather than by a broader engine-family range. Its purpose is propane tri-fuel conversion. That makes the generator model number the decisive compatibility check; the name alone does not establish a fit for other Briggs generators. Buyers seeking a complete kit with a defined regulated-supply connection may prefer one of the other model-specific options, whose fuel-system requirements are clearer.
Bottom line: Choose this only when the generator is model 030728 and a conversion carburetor is what you need.
Briggs and Stratton Propane/Natural Gas Kit

This is the broadest-named option, described as a propane and natural gas conversion kit for Briggs and Stratton rather than for a particular model. Its claims focus on construction and installation, not fuel pressure or a regulated-supply connection. That makes the compatibility question more important here than with the kits that name a generator or engine model. Treat the general fit wording cautiously and verify the precise generator or engine match before choosing it.
Bottom line: Consider this only after confirming that the kit matches your exact Briggs and Stratton model.
402707/422707 Impco Low-Pressure Kit

This complete tri-fuel kit names Briggs Stratton engine models 402707 and 422707, making it distinct from the generator-specific choices. It supports gasoline, low-pressure propane, and low-pressure natural gas, and connects to an already regulated system. The setup is a limitation if your fuel supply is not regulated; do not assume this kit provides that regulation. Match the engine number carefully, since its fit does not establish compatibility with other Briggs models.
Bottom line: Pick this for a 402707 or 422707 engine connected to an already regulated system.
How to choose a Briggs and Stratton conversion kit
Start with the engine or generator model number, not the brand name alone. These options name fits ranging from generator models such as 030728 to engine models 402707 and 422707, so a Briggs badge does not establish compatibility. Next, match the fuel supply: some kits connect to an already regulated system, while XR Storm Responder 6250 Conversion Kit specifies a 9–13.8-inch water-column inlet range. A tri-fuel kit is intended to support gasoline as well as gaseous fuels, but its model and supply requirements still apply. If the model number or inlet pressure does not match, do not choose a kit based only on its fuel label.
Propane supply pressure and regulation
Low-pressure propane conversion depends on the pressure at the kit inlet, not simply on having a propane tank. One kit here gives a specific 9–13.8-inch water-column range; two others say they connect to an already regulated system. A regulator reduces tank pressure to a usable appliance pressure, and the correct regulator depends on the conversion system and fuel demand. Never substitute an unregulated tank connection for a low-pressure supply. Before ordering, compare the kit’s inlet requirement with the regulator output and connection setup; for options without a pressure range, confirm that requirement with the seller or manufacturer.
Conversion carburetors and kit-style systems
A conversion carburetor replaces or adapts the engine’s fuel-metering components, while other conversion approaches add a mixer or gaseous-fuel connection to the intake. The products here include one explicitly called a conversion carburetor and several described as complete kits, but those labels alone do not show every included component. Use this distinction to frame questions about the installation, not to assume a particular kit contains a regulator, hose, or fitting. A tri-fuel setup is useful when retaining gasoline operation matters; a propane-only approach may be simpler, but verify the actual fuel options for the specific kit.
Safe generator use with propane
Run a portable generator outdoors only; carbon monoxide can build to lethal levels indoors, in garages, and near open windows or doors. Keep the exhaust directed away from buildings and openings, and follow the clearances in the generator manual. Propane adds a separate leak and fire hazard: shut off the supply if you smell gas, avoid ignition sources, and do not operate equipment with a damaged hose or connection. After conversion, check the fuel connections for leaks using an approved method before operation. A propane kit does not change the generator’s carbon-monoxide or exhaust risks.
Frequently Asked Questions
How do I identify the right Briggs and Stratton kit?
Match the full engine or generator model number to the fit named for the kit. Model 030728, Genpower 6000 257417, and engines 402707/422707 are distinct applications, so a matching brand is not enough.
Can I connect a low-pressure kit directly to a propane tank?
No; a low-pressure conversion requires a regulated supply. One kit specifies 9–13.8 inches of water column, and other options say they connect to an already regulated system.
What does tri-fuel mean on a generator conversion?
Tri-fuel means the conversion is intended to support gasoline, propane, and natural gas. Confirm that the exact kit supports the fuel and supply setup you plan to use.
Can I run a converted generator inside a garage?
No. Portable generators produce carbon monoxide, so operate them outdoors and away from doors, windows, and other openings, even with propane as the fuel.
Do all conversion kits include a regulator and hose?
No; the kit descriptions differ, and some are designed for an already regulated system. Confirm the included components and the required inlet pressure for your exact kit before installation.