4 to 20 mA Signal Generators Compared by Output

For a 4 to 20 mA signal generator, the Riiai SG003A stands out because it combines 0 to 24 mA current with voltage and frequency modes; choose another model if you need a simpler knob-controlled output or a dedicated calibrator.

These tools create analog signals for checking or adjusting control inputs, so confirm the required active or passive loop type and output range for your equipment before ordering.

We earn a commission if you buy through links on this page. As an Amazon Associate I earn from qualifying purchases. Products are compared on manufacturer specifications, not hands-on testing.

  • Best overall: Riiai SG003A – Adds voltage and pulse modes to a 0 to 24 mA current output, with 0.01 mA adjustment precision.
  • Best for bipolar voltage: Riiai 0–10 V / 0–22 mA Generator – Provides adjustable -10 V to +10 V output alongside current output up to 22 mA.
  • Best for compact use: LB78 Signal Generator Calibrator – A 4.3 × 2.6 × 0.8-inch calibrator with an LCD and a built-in quick-break fuse.
Product Best for Current output Voltage output Controls or display Shop
Riiai SG003A Multiple signal types 0–24 mA 0–24 V 2.4-inch color TFT Check Price on Amazon
Riiai 0–10 V / 0–22 mA Generator Bipolar voltage output 0–22 mA −10 to +10 V 4-digit display; encoder Check Price on Amazon
Adjustable ±12 V / 0–24 mA Generator PWM signal output 0–24 mA ±12 V PWM: 1–150 kHz Check Price on Amazon
DROK 0–10 V / 0–20 mA Generator Simple knob adjustment 0/4–20 mA 0–10 V Multi-cycle potentiometer Check Price on Amazon
LB78 Signal Generator Calibrator Compact calibrator 4–20 mA mV signal source LCD; independent keys Check Price on Amazon

4 to 20 mA Signal Generators

Compare each generator’s current range and additional outputs against the signals your equipment accepts.

Riiai SG003A

Riiai SG003A

The SG003A is the most versatile option here for signal types, adding frequency output to current and voltage modes. Its current and voltage outputs each span 0 to 24, with 0.01 mA and 0.01 V precision; the frequency mode spans 0 to 9999 Hz. The 2.4-inch TFT screen and rechargeable 3000 mAh battery suit bench work where switching between signal types is useful. Brand specifications also identify an XMT passive-current mode, so check that mode against the loop configuration you need to simulate.

Bottom line: Choose this when you need current, voltage, and pulse output in one instrument.

Check Price on Amazon

Riiai 0–10 V / 0–22 mA Generator

Riiai 0–10 V / 0–22 mA Generator

The bipolar voltage range distinguishes this Riiai from the other compact generators: it can output from −10 V to +10 V, while current output covers 0 to 22 mA. An encoder knob adjusts either output, and a mode button switches the four-digit display between voltage and current; alternate display modes include percent and 0–50 Hz. The built-in 1000 mAh rechargeable battery is charged through micro USB. Its current ceiling is lower than the 24 mA models, which matters when a test requires output above 22 mA.

Bottom line: Pick this when negative voltage output matters more than a 24 mA current ceiling.

Check Price on Amazon

Adjustable ±12 V / 0–24 mA Generator

Adjustable ±12 V / 0–24 mA Generator

The defining extra on this generator is adjustable PWM, with a 1–150 kHz frequency range and 0–100% duty cycle. Its current output is settable from 0 to 24 mA, with 4–20 mA as the factory default, and voltage output reaches ±12 V. After calibration, the accuracy is 0.05 mA for current and 0.03 V for voltage. A 1500 mAh battery powers it, but runtime is given as 1–5 hours depending on output load, so it may be a poor fit for extended sessions away from charging.

Bottom line: Choose this if PWM testing is part of the job alongside analog current output.

Check Price on Amazon

DROK 0–10 V / 0–20 mA Generator

DROK 0–10 V / 0–20 mA Generator

The DROK keeps adjustment simple with a multi-cycle precision potentiometer rather than a digital display or mode-heavy interface. One module generates a selectable 0 or 4–20 mA current signal and a 0–10 V voltage signal, making it suited to basic PLC or panel checks that need those two common outputs. The specifications focus on the output modes and potentiometer, so this is less suitable when you need an accuracy figure, rechargeable power, or additional frequency functions. Match the current mode to the input you are checking.

Bottom line: Pick this for straightforward analog adjustment with a physical potentiometer.

Check Price on Amazon

LB78 Signal Generator Calibrator

LB78 Signal Generator Calibrator

The LB78 is positioned as a calibrator for maintenance work across PLC, DCS, ESD, valves, and frequency converters, rather than as a general-purpose pulse generator. Its functions include 4–20 mA, 0–10 V, and mV signal sourcing, with an LCD and separate keys for the functions. A built-in one-time quick-break fuse is intended to guard against damage from misconnecting 110 V; do not treat that protection as permission to connect mains voltage.

Bottom line: Choose this compact calibrator for maintenance tasks needing mV as well as current and voltage signals.

Check Price on Amazon

How to choose a 4 to 20 mA signal generator

Start by matching the output mode and usable range to the input you plan to check. A standard 4–20 mA loop uses 4 mA as the live zero and 20 mA as the upper endpoint; some devices also accept 0–20 mA, which is not interchangeable in every control setup. For a transmitter-style loop, determine whether the instrument must source current actively or simulate a passive transmitter. Choose a model with a 24 mA ceiling if you need margin above 20 mA; for bipolar voltage work, select a model whose output crosses zero. A 0–10 V output will not substitute for a negative voltage source.

Active and passive current loop fit

Current-loop compatibility depends on which device supplies loop power, not just the displayed mA range. In an active-source setup, the signal generator provides current; in a passive simulation, an external loop supply drives the current through the simulator. Before connecting, identify the input terminals and whether the receiving device already provides loop power, since placing two supplies in one loop can cause a wiring fault or damage. For a typical 250-ohm receiver, 4–20 mA produces a 1–5 V drop by Ohm’s law. Use that conversion only when the actual input resistance is 250 ohms, and never exceed the receiver’s documented electrical limits.

Current signal checks and safe wiring

Verify the loop’s polarity and expected current before attaching a generator to a powered control circuit. A 4–20 mA instrument loop commonly uses two wires, but four-wire devices and isolated inputs use different arrangements; follow the device terminal diagram rather than assuming all terminals are alike. Set the output to 4 mA for the low endpoint and 20 mA for the high endpoint when checking a standard span. Keep mains voltage away from signal terminals: a fuse or short-circuit feature does not make a signal generator a mains-rated meter. Disconnect power before changing wiring unless the circuit procedure explicitly allows live-loop work.

Choosing between PWM, voltage, and current output

Choose a current source for analog loop inputs, a voltage source for voltage-rated analog inputs, and PWM only for equipment designed to read pulse width or frequency. PWM frequency and duty cycle are separate variables: frequency sets cycles per second, while duty cycle is the fraction of each cycle spent high. A 1 kHz, 50% PWM signal is not equivalent to a steady 4–20 mA signal, even if the receiving device can display a process value. For analog voltage compatibility, confirm whether the input expects unipolar 0–10 V or bipolar voltage; a bipolar output can produce negative voltage that a unipolar input may not tolerate.

Calibrator range and resolution

Range and resolution answer different questions: range is the lowest-to-highest output, while resolution is the smallest adjustment increment. For a 4–20 mA span, 0.01 mA resolution divides the 16 mA span into 1,600 steps, whereas 0.05 mA accuracy describes closeness to the setpoint after calibration. Do not treat a fine display increment as proof of accuracy. When calibrating a control input, use a reference meter or documented calibration procedure if the required tolerance is tighter than the generator’s accuracy. Battery runtime also changes with output load, so reserve charging time for long sessions.

Frequently Asked Questions

What does 4 to 20 mA mean in a control loop?

A 4–20 mA loop represents a process range with 4 mA as live zero and 20 mA as full scale. Many systems map that 16 mA span linearly to a sensor range, while 0 mA can indicate a broken loop or loss of power.

How do I convert loop current to voltage?

Use Ohm’s law: voltage equals current multiplied by resistance. Across a 250-ohm input, 4–20 mA corresponds to 1–5 V; confirm the receiver resistance before using that conversion.

Can a signal generator test a powered current loop?

Only if its source or simulation mode matches the loop wiring. Determine whether the generator or the receiver supplies loop power, because two power sources in one loop can create a wiring fault.

What is the difference between 0–20 mA and 4–20 mA?

A 0–20 mA range starts at zero current, while 4–20 mA uses 4 mA as its live-zero endpoint. Use the range expected by the receiving instrument; substituting one span for the other changes the signal interpretation.

What does PWM frequency tell me?

PWM frequency is the number of pulse cycles per second, measured in hertz; duty cycle is the percentage of each cycle spent at the high level. Check both values against the receiving device’s input requirements.