Generac Oil Pressure Switches Compared by Fit

For a generator that calls for 0L2917C, choose UGP 0L2917C Replacement because it matches that part number, 10 PSI setting and normally closed contact type. DVPARTS 0L2917C Switch is another 0L2917C replacement with a 1/4-18 NC specification.

For a generator requiring 0G6820 or 0C30250SRV, consider Generac 0C30250SRV Oil Pressure Kit or DVPARTS 0G6820 Switch instead; the correct switch depends on the generator’s required part number.

We earn a commission if you buy through links on this page. As an Amazon Associate I earn from qualifying purchases. Products are compared on manufacturer specifications, not hands-on testing.

Product Best for Part number Pressure setting Thread/contact Shop
UGP 0L2917C Replacement 0L2917C replacement 0L2917C 10 PSI — / normally closed Check Price on Amazon
DVPARTS 0L2917C Switch Thread specification 0L2917C, 0C3025, 0C30250SRV, 0G6820 10 PSI 1/4-18 / NC Check Price on Amazon
Generac 0C30250SRV Oil Pressure Kit Genuine OEM part 0C30250SRV, replaces 0G6820 — 1/4 in NPTF / normally closed Check Price on Amazon
DVPARTS 0G6820 Switch 0G6820 replacement 0G6820 10 PSI 1/4-18 / NC Check Price on Amazon
Generac 0G68200SRV Switch OEM 0G68200SRV 0G68200SRV — 1/4 in NPTF / normally closed Check Price on Amazon

Generac Oil Pressure Switches

Match the switch’s part number and electrical and threaded connection to the generator before choosing a replacement.

UGP 0L2917C Replacement

UGP 0L2917C Replacement

UGP 0L2917C Replacement is the direct match here for Generac 0L2917C: its 10 PSI setting and normally closed design match the specified replacement part. That makes it the focused choice when the generator calls for that exact number. The switch is a small threaded component in the oil pressure circuit; the pressure rating and contact arrangement both matter for correct operation. Its fit is limited to 0L2917C, so it is not the choice for a generator calling for 0G6820 or another switch number. Confirm the generator’s required part number before selecting a replacement.

Bottom line: Choose this when the generator requires 0L2917C and a normally closed 10 PSI switch.

Check Price on Amazon

DVPARTS 0L2917C Switch

DVPARTS 0L2917C Switch

DVPARTS 0L2917C Switch stands out for naming several related part numbers and giving a 1/4-18 NC specification alongside its 10 PSI rating. It may suit buyers whose generator calls for one of those numbers and whose existing connection matches the thread and contact type. The maker gives a 12-month warranty. A shared part-number reference does not establish that every generator using one of those numbers has the same wiring or fit, so verify the required number and connection before choosing it. The specs make this option more useful when thread information is part of the replacement decision.

Bottom line: Choose this if the part-number cross-reference and 1/4-18 NC connection match your generator.

Check Price on Amazon

Generac 0C30250SRV Oil Pressure Kit

Generac 0C30250SRV Oil Pressure Kit

Generac 0C30250SRV Oil Pressure Kit is the genuine Generac option in this group, identified as 0C30250SRV and a replacement for 0G6820. Its connection is 1/4-inch NPTF, with a normally closed switch. This is the clearest fit when the generator’s required number is 0C30250SRV or the specified 0G6820 replacement. Unlike options that provide a 10 PSI setting, this product’s specifications do not give a pressure threshold, so it is a weaker choice if matching a known pressure value is essential. Confirm the required part number before choosing it.

Bottom line: Choose this for a genuine Generac replacement when 0C30250SRV or its 0G6820 fit is required.

Check Price on Amazon

DVPARTS 0G6820 Switch

DVPARTS 0G6820 Switch

DVPARTS 0G6820 Switch focuses on 0G6820 and names compatible Generac 0044511, 0057340, 0057350, GP15000E and GP17500E models that require that number. It specifies a 10 PSI, 1/4-18 NC switch, giving a useful match when both the application and connection agree. A 12-month warranty is also stated. Because the named model fit applies only to models requiring 0G6820, the model family alone is not enough to establish fit for every version. This option is distinct from a 0L2917C-specific replacement.

Bottom line: Choose this when the generator requires 0G6820 and the models and switch specs match.

Check Price on Amazon

Generac 0G68200SRV Switch

Generac 0G68200SRV Switch

Generac 0G68200SRV Switch is identified as a Generac oil pressure switch with a 0G68200SRV part number and a 1/4 NPTF normally closed connection. It is a straightforward option when that exact number is required and the generator’s connection matches. Match the complete number carefully: 0G68200SRV is not the same written number as 0G6820.

Bottom line: Choose this only when the required part number is 0G68200SRV and the connection matches.

Check Price on Amazon

How to Choose a Generac Oil Pressure Switch

Start with the part number required by the generator, then compare pressure setting, contact type and thread. These switches can look similar while serving different applications, so a matching brand or model family alone is not a sufficient fit check. A normally closed (NC) switch has a closed circuit in its normal unactuated state; the equipment’s pressure circuit relies on the intended switching behavior. The 10 PSI rating is the switch point, not the engine’s oil capacity or a recommendation for oil grade. If a replacement must match an existing switch, compare its stamped number and connection with the required part number. Do not substitute a switch solely because its thread appears to fit.

Thread and Contact Compatibility

Thread and electrical contact must both match the generator. A 1/4-18 threaded designation identifies the nominal thread size and 18 threads per inch; NPT and NPTF are related tapered pipe-thread forms, but the suffix is still worth matching rather than assuming interchangeability. NC means normally closed and describes contact state, not connector shape or wire count. Before installation, isolate generator power and follow the equipment’s service procedure; an incorrectly wired oil pressure circuit can cause a shutdown circuit to behave improperly. Keep the switch clean during installation and avoid forcing a mismatched thread into the engine port. Have a qualified service technician handle the replacement if you are unsure about the wiring or sealing method.

Part Numbers and Application Fit

Use the exact part number as the deciding fit rule: if the generator requires 0L2917C, select an option identified for 0L2917C; if it calls for 0G6820 or 0C30250SRV, use an option that names that application. Related numbers do not automatically mean universal interchangeability. A model series can contain revisions, so verify the generator’s exact requirement rather than relying only on a broad family name. This table separates the main distinctions among the switches here.

Required fit Option to consider Key check
0L2917C UGP 0L2917C Replacement or DVPARTS 0L2917C Switch Confirm 10 PSI and contact/thread match
0G6820 or 0C30250SRV Generac 0C30250SRV Oil Pressure Kit or DVPARTS 0G6820 Switch Match exact number and connection
0G68200SRV Generac 0G68200SRV Switch Do not confuse with 0G6820

Replacement Checks Before Installation

Confirm the required part number, pressure rating and connection before removing the old switch. Oil pressure switches form part of a protective circuit, so bypassing the switch or installing a different contact type can defeat the intended shutdown behavior. Stop the generator, let hot components cool and disconnect its starting power according to the service procedure before working near the engine. Check for oil leakage after installation and confirm that the generator operates as intended; an oil pressure warning or shutdown should not be ignored. Use the generator service manual for tightening and sealing instructions because excessive force can damage a tapered port, while a poor seal can leak oil.

Frequently Asked Questions

What does a 10 PSI oil pressure switch rating mean?

A 10 PSI rating identifies the pressure point associated with switch operation. It is not an oil-fill quantity, and a replacement should match the generator’s specified switch rating.

Can I replace 0G6820 with 0L2917C?

Do not assume those part numbers are interchangeable. Use the exact number required for the generator; similar pressure and thread specifications do not establish application fit.

What does 1/4-18 mean on a pressure switch?

The designation refers to a nominal 1/4-inch pipe thread with 18 threads per inch. NPT and NPTF are related tapered thread forms, but confirm the exact connection the generator requires.

Should I bypass a generator oil pressure switch?

No; bypassing a protective switch can disable the intended oil pressure shutdown function. Stop operation if the switch circuit signals a problem and diagnose the cause rather than running the generator without protection.