Lyman Gen 6 Powder Dispenser: Models Compared
Lyman Gen6 Digital Powder Measure is the match for a Lyman Gen 6 powder dispenser search; choose it if the Gen6 model is your priority, since its maker gives no dispensing accuracy or capacity figure. Choose another electronic dispenser if you want a 0.1-grain accuracy figure, touch controls, or app connectivity.
We earn a commission if you buy through links on this page. As an Amazon Associate I earn from qualifying purchases. Products are compared on manufacturer specifications, not hands-on testing.
- Best overall: Lyman Gen6 Digital Powder Measure – It is the requested Gen6 model, though its maker does not give a capacity or accuracy figure.
- Best for app control: RCBS ChargeMaster Link – Bluetooth pairs the dispenser with the RCBS app, and it has a 2,000-grain capacity.
- Best for phone or touch control: Frankford Arsenal Intellidropper – It can be operated from its touchscreen or app and has a stated ±0.1-grain accuracy.
- Best for adjustable trickling: Hornady Auto Charge Pro – Customizable trickle speeds and settings for up to four loads distinguish this model.
| Product | Best for | Accuracy | Capacity | Controls | Shop |
|---|---|---|---|---|---|
| Lyman Gen6 Digital Powder Measure | Gen6 shoppers | — | — | Digital measure | Check Price on Amazon |
| RCBS ChargeMaster Link | Bluetooth controls | 0.1 grain | 2,000 grains | Touchscreen, Bluetooth app | Check Price on Amazon |
| Frankford Arsenal Intellidropper | App database use | ±0.1 grain | — | Touchscreen, phone app | Check Price on Amazon |
| Hornady Auto Charge Pro | Custom trickle settings | 0.1 grain | Large capacity | Backlit touchscreen | Check Price on Amazon |
Lyman Gen 6 Powder Dispensers and Alternatives
Compare the requested Gen6 model with other electronic dispensers by their precision, capacity, and controls.
Lyman Gen6 Digital Powder Measure

The Lyman Gen6 is the direct match for shoppers seeking this digital powder measure. The product dimensions supplied are 4.69 × 3.46 × 1.50 inches; these are product dimensions rather than package dimensions. Choose this model when matching the Gen6 name and 115V configuration matters more than comparing a precision figure or connected controls.
Bottom line: Pick this if you specifically want the Gen6 model and its 115V configuration.
RCBS ChargeMaster Link

Bluetooth app pairing is the feature that separates this RCBS dispenser from the other choices. It has a 2,000-grain capacity, a 16-segment LCD touchscreen, and a quick warm-up feature; the maker gives an accuracy figure of 0.1 grain. The unit can also run on an external battery pack. This is an alternative rather than the requested Gen6 model, so choose it when connected operation and a capacity are useful. Buyers who prefer a measure without app pairing may find that extra control pathway unnecessary.
Bottom line: Choose this if Bluetooth app control and a 2,000-grain capacity matter.
Frankford Arsenal Intellidropper

The Intellidropper pairs touch operation with a phone app that includes reloading databases and stored load data. The maker specifies ±0.1-grain accuracy, self-optimizing powder calibration, and both auto and manual trickle capability. Its large backlit LCD provides a separate on-unit control option, while the app works with iPhone, Windows, and Google platforms as described by the maker. This model suits people who value app-based reference tools over the Gen6 name.
Bottom line: Pick this if app-based load data and dual control options are priorities.
Hornady Auto Charge Pro

Customizable trickle speeds make the Hornady Auto Charge Pro distinct among these alternatives. The maker says accuracy is within 0.1 grain and the unit can store settings for up to four custom loads, in addition to a factory setting. It also has a backlit touchscreen, a removable trickler tube, a built-in bubble level, and a large powder capacity. Choose this model for adjustable dispensing behavior rather than for the Gen6 model identity.
Bottom line: Choose this if adjustable trickle speeds and saved load settings fit your workflow.
How to Choose an Electronic Powder Dispenser
Start with the maximum charge capacity and the precision figure, then compare how each unit is operated. A 2,000-grain capacity is 4.57 ounces by weight, but capacity alone does not establish whether a dispenser is suitable for a particular charge. A 0.1-grain accuracy claim describes the maker’s precision; it does not replace weighing each charge on a properly checked scale. Decide whether you want app pairing, on-device touch controls, or adjustable trickle behavior. For a workflow requiring a verified maximum charge above 2,000 grains, confirm capacity before selecting a model whose capacity is not supplied.
Electronic measures dispense powder toward a selected charge, commonly by faster delivery followed by slower trickling near the target. Different powder granule shapes and flow characteristics can affect dispensing pace, which is why adjustable trickle control may matter to some reloaders.
What Accuracy and Capacity Mean
Grains are the standard unit used for powder charge weights in reloading; 1 grain equals 1/7,000 pound. A 0.1-grain increment is one tenth of a grain, but an advertised accuracy figure is not the same as a guaranteed result for every powder or operating condition. Capacity describes the maximum weight the dispenser can hold or handle, not the charge weight it should dispense for a cartridge. Use published load data for the exact cartridge, bullet, and powder combination; never extrapolate a charge from another component combination.
Capacity, accuracy, and control features answer different questions, so compare each separately before choosing.
| Need | Feature to compare | Why it matters |
|---|---|---|
| Known maximum load size | Capacity in grains | Confirms the unit’s limit |
| Fine charge control | Accuracy figure and scale check | Supports charge verification |
| Connected workflow | App and Bluetooth support | Changes how settings or data are accessed |
| Adjustable delivery | Manual or customizable trickle | Changes control over the final dispensing stage |
Safe Powder Measuring Practices
Use one powder at a time and keep it in its original, clearly identified container; mixing powders or losing identification can create a dangerous loading error. Set charges only from current published data for the exact components and cartridge, and confirm charge weight with a suitable scale rather than relying solely on the dispenser’s target setting. Keep powder away from flame, sparks, and heat, and avoid distractions while measuring. Never exceed a published maximum charge, and do not use a charge intended for one bullet or powder with another.
Before dispensing, make sure the work area is clear of other powder containers and that the scale is zeroed according to its operating procedure. Empty and clean the measure when changing powders to prevent residue from being mistaken for the next powder.
When to Verify a Charge by Scale
Verify each dispensed charge on a separate scale during setup and whenever you change the powder, target charge, or operating conditions. A dispenser’s 0.1-grain accuracy is a specification, not proof that every charge lands exactly on target. Keep the scale on a stable, level surface and allow electronic equipment to warm up as its maker requires; environmental changes and vibration can affect scale readings. If a reading is inconsistent, stop and troubleshoot rather than loading a questionable charge.
For any unit without a capacity or precision figure, confirm that specification before relying on it for a particular workflow. Recheck a charge whenever a setup change could alter dispensing or weighing.
Frequently Asked Questions
What does 0.1-grain accuracy mean on a powder dispenser?
A 0.1-grain figure is one tenth of a grain, and 1 grain equals 1/7,000 pound. Treat the figure as a maker’s specification and verify charge weight with a scale.
Should I verify charges from an electronic dispenser?
Yes, verify charge weight on a suitable scale, especially during setup or after changing powder or target charge. A dispenser’s accuracy claim does not replace checking the actual charge.
Can I use one charge for different powders?
No, use published load data for the exact powder and component combination. Powders are not interchangeable by charge weight, and they should remain clearly identified in their original containers.
How much powder does a 2,000-grain capacity hold?
A 2,000-grain capacity is about 4.57 ounces by weight because 7,000 grains equal 1 pound. That capacity is a device limit, not a recommended charge for any cartridge.
Why does an electronic measure trickle powder slowly?
Many electronic measures dispense faster at first and then trickle near the target to refine the charge. Granule shape and flow characteristics can change how quickly powder feeds.