SH Capacitor 350 370V 50 60Hz: Fit Compared
For a 50 µF, 370VAC replacement in a 50/60Hz motor circuit, IWIWE 50 µF CBB65 Capacitor is the closest match because it supports 370VAC and lists a ±5% tolerance. Choose 50 µF × 370VAC Round Capacitor if you need the round 370VAC form and quick-connect terminals; BOJACK 50 µF CBB60 Capacitor is a 250VAC CBB60 capacitor and is only relevant when the original circuit calls for that lower rating.
Match the original capacitance and voltage rating before replacing a motor capacitor; higher capacitance is not a safe substitute.
We earn a commission if you buy through links on this page. As an Amazon Associate I earn from qualifying purchases. Products are compared on manufacturer specifications, not hands-on testing.
- Best overall: IWIWE 50 µF CBB65 Capacitor – It combines 50 µF, 370VAC compatibility, ±5% tolerance and 50/60Hz operation.
- Best for round format: 50 µF × 370VAC Round Capacitor – It is a 50 µF, 370VAC round run capacitor with 0.250-inch quick-connect terminals.
- Best for 250VAC motors: BOJACK 50 µF CBB60 Capacitor – Its 50 µF CBB60 rating is 250VAC for a circuit requiring that voltage.
| Product | Best for | Capacitance | Rated voltage | Form / terminals | Shop |
|---|---|---|---|---|---|
| IWIWE 50 µF CBB65 Capacitor | Broad voltage compatibility | 50 µF ±5% | 370/440/450VAC | CBB65/CBB65B; — | Check Price on Amazon |
| 50 µF × 370VAC Round Capacitor | Round terminal replacement | 50 µF | 370VAC | Round; 0.250-inch quick-connect | Check Price on Amazon |
| BOJACK 50 µF CBB60 Capacitor | 250VAC applications | 50 µF ±5% | 250VAC | CBB60; 2-wire | Check Price on Amazon |
50 µF SH Capacitors for 350–370V Circuits
Compare the capacitance, voltage rating and construction before matching a replacement to the motor circuit.
IWIWE 50 µF CBB65 Capacitor

The IWIWE is the broadest voltage match here, with 50 µF capacitance and compatibility across 370, 440 and 450VAC systems. Its CBB65/CBB65B construction is intended for run/start motor applications, and the maker specifies 50/60Hz operation and a working temperature range of -40°C to +70°C. It may suit a replacement when those ratings match the original capacitor. The product is not a universal fit: confirm the original capacitance, voltage and physical/terminal arrangement, since a voltage range alone does not establish mechanical compatibility.
Bottom line: Choose this when the original requires 50 µF and its voltage and fit match.
50 µF × 370VAC Round Capacitor

The round form and 0.250-inch quick-connect terminals distinguish this 50 µF, 370VAC run capacitor. Those details help when replacing an existing round unit with the same connection style; its dimensions are 1.89 inches high and wide and 4.49 inches long. The maker says the capacitor conforms to EIA-456-A and reports a 60,000-hour life target. That reliability claim does not make it suitable for a circuit needing a higher voltage rating, and dimensions may change, so check clearances and the original rating before selecting it.
Bottom line: Pick this for a matching round 370VAC unit with quick-connect terminals.
BOJACK 50 µF CBB60 Capacitor

The BOJACK differs from the 370VAC options in its 250VAC rating and CBB60 cylindrical construction. It is a 50 µF, ±5% motor run capacitor for 50/60Hz applications, with a two-wire connection and a compact stated size of about 1.61 inches high by 1.65 inches long and wide. The maker identifies uses such as unidirectional motors, compressors and air conditioners. Its lower voltage makes it unsuitable as a substitute where the original calls for 350 or 370VAC; select it only for a circuit whose original electrical specification calls for 250VAC.
Bottom line: Choose this only when the required circuit rating is 250VAC.
How to choose a 50 µF motor capacitor
Match capacitance first, then select a voltage rating at least as high as the original capacitor. Motor run capacitors are rated in microfarads (µF); a ±5% tolerance means a 50 µF unit can measure from 47.5 to 52.5 µF. The VAC rating is the maximum intended AC voltage, not a target to exceed casually. A 440VAC capacitor can generally replace a 370VAC unit when capacitance, duty and physical fit match, but a 370VAC unit should not replace a 440VAC part. Check whether the motor calls for a run or start capacitor: those designs are not automatically interchangeable. Match terminal type and body clearance as well as electrical ratings.
What 50/60Hz and SH mean for fit
A 50/60Hz marking indicates intended operation on either common mains frequency, but it does not establish compatibility with every motor. “SH” is commonly used as a safety/protection marking on capacitor cases, while CBB designations identify capacitor construction families; the exact case label and circuit role still matter. Round and cylindrical bodies can have different mounting needs even when their electrical ratings match. For a replacement, read the original µF, VAC, frequency, and terminal arrangement directly from its label, then compare the mounting footprint. If the original label requires 350VAC or another rating not directly offered, choose a capacitor rated at least that high and confirm fit rather than treating a lower rating as equivalent.
Run capacitor safety and replacement mistakes
A motor capacitor can retain a dangerous charge after power is disconnected, so isolate the circuit and have a qualified person discharge and verify it before handling. Shorting terminals with a screwdriver can cause arcing and damage; use an appropriately rated resistor and meter only if trained to do so. Photograph or label wire positions before removal, since a wrong connection can damage the motor or create an electrical hazard. Never increase µF to address a motor that struggles to start: the correct capacitance is determined by the motor design. A replacement also needs adequate VAC rating, suitable temperature/environment rating, and the same run/start duty. Stop if wiring, case damage or circuit ratings are unclear.
Quick comparison by circuit requirement
Use the motor’s original capacitor label as the deciding reference; the closest matching electrical rating and physical connection are the appropriate starting point.
| Need | Candidate | What must match |
|---|---|---|
| 50 µF at 370VAC or higher | IWIWE 50 µF CBB65 Capacitor or 50 µF × 370VAC Round Capacitor | Original voltage, duty and terminals |
| Round body with quick-connect tabs | 50 µF × 370VAC Round Capacitor | Terminal fit and available clearance |
| 50 µF at 250VAC | BOJACK 50 µF CBB60 Capacitor | Original circuit rating and CBB60 form |
Frequently Asked Questions
Can a 440VAC capacitor replace a 370VAC capacitor?
Generally, yes, when the capacitance, run/start duty, frequency and physical fit also match. The voltage rating must not be below the original rating.
Can I use 370VAC where the motor needs 440VAC?
No; a 370VAC rating is below a 440VAC requirement. Select a capacitor rated at least 440VAC with the specified capacitance and duty.
What does ±5% mean on a 50 µF capacitor?
It allows a measured capacitance from 47.5 to 52.5 µF. The replacement should stay within the original motor’s specified capacitance tolerance.
Can a run capacitor replace a start capacitor?
Not automatically; run and start capacitors serve different circuit duties and may have different capacitance ranges and operating times. Use the type specified for the motor.
How should a motor capacitor be handled safely?
Disconnect power and treat the capacitor as charged until safely discharged and verified with a meter. Stored electrical charge can cause serious shock, so untrained users should have a qualified technician perform the replacement.