RV Vent Cap Replacement: Compare 5 Fits and Kits

For an RV vent cap replacement, Two-Pack Spring-Tension Vent Caps is the closest match when you need a cap for a pipe up to 2 inches and a spring-tension attachment. Choose a base-and-hardware kit instead if the existing base is missing or damaged; confirm the pipe’s outside diameter and whether its base can be reused before ordering.

We earn a commission if you buy through links on this page. As an Amazon Associate I earn from qualifying purchases. Products are compared on manufacturer specifications, not hands-on testing.

Product Best for Pipe fit Package Mounting parts Shop
Two-Pack Spring-Tension Vent Caps Cap-only replacement Up to 2 in. 2 caps Spring tension Check Price on Amazon
Camco 40034 Replacement Cap UV-inhibitor cap Up to 2 in. 1 cap Cap only Check Price on Amazon
Aussio 2-Pack Roof Vent Kits Putty and screws 1–2⅜ in. OD 2 kits Putty tape, screws Check Price on Amazon
Sporthfish 2-Pack Vent Caps Wide pipe range 1–2⅜ in. 2 caps Base included Check Price on Amazon
Camco 40033 Replace All Vent Kit Full vent kit 1–2⅜ in. OD 1 kit Hardware, putty tape Check Price on Amazon

RV Vent Cap Replacement Options

Match the pipe diameter first, then decide whether you need only the cap or a full base and mounting kit.

Two-Pack Spring-Tension Vent Caps

Two-Pack Spring-Tension Vent Caps

For a cap-only repair, this two-pack replaces a lost or damaged cover and uses spring-tension to attach to the vent pipe. The cap is polypropylene plastic with iron components, and the fit is for pipe up to 2 inches; the compatibility range also gives 1 to 2-3/8 inches outside diameter. It suits owners who can reuse the existing roof base and want a spare cap. It does not include a replacement base, screws, or putty tape, so it is not the right choice if the roof mounting assembly needs replacement.

Bottom line: Choose this when the existing base is sound and you need spring-tension caps.

Check Price on Amazon

Camco 40034 Replacement Cap

Camco 40034 Replacement Cap

Camco 40034 Replacement Cap is the single-cap option among the exact-fit replacements, sized for a plumbing vent pipe up to 2 inches. Camco says its UV inhibitors are intended to extend the cap’s life; the cap is polar white and replaces a lost or damaged cover. It is a straightforward match when the current base remains usable and you want one replacement cap rather than a two-pack. The base is not included, so measure the pipe and check the existing base’s condition before selecting this cap.

Bottom line: Pick this for a one-cap repair when the base can stay in place.

Check Price on Amazon

Aussio 2-Pack Roof Vent Kits

Aussio 2-Pack Roof Vent Kits

Unlike cap-only replacements, Aussio 2-Pack Roof Vent Kits includes putty tape and screws for roof mounting. Each white plastic cover is 3 inches tall with a 5.3-inch base diameter, and the pipe range is 1 to 2-3/8 inches outside diameter. The two-pack suits a repair where the existing cover or mounting hardware needs replacing, and its six base screw holes give the installer mounting points to work with. Its package adds parts that may be unnecessary for a cap-only repair, so compare the included base dimensions with the roof opening and old mounting footprint.

Bottom line: Choose this when you need two covers plus roof-mounting supplies.

Check Price on Amazon

Sporthfish 2-Pack Vent Caps

Sporthfish 2-Pack Vent Caps

Sporthfish 2-Pack Vent Caps is a two-cover option with a broad 1- to 2-3/8-inch pipe fit and a 5.3-inch base diameter. The 3-inch-tall plastic caps are intended for RV sewer plumbing vents, where the stack vents tank gases and the cover helps keep debris and water out. This makes the pair suitable when you need matching covers for two roof vents. Unlike a cap-only design, the product is described as a roof cover, but its components do not identify putty tape or screws; verify the mounting needs for your roof before choosing it.

Bottom line: Pick this for two vents with pipes within its fit range.

Check Price on Amazon

Camco 40033 Replace All Vent Kit

Camco 40033 Replace All Vent Kit

Camco 40033 Replace All Vent Kit is a full replacement kit rather than a cap-only part, with hardware and putty tape included. It fits pipe from 1 to 2-3/8 inches outside diameter and is described as easy to install. The kit is suited to a roof vent whose mounting components need replacing, particularly when the old cap and base should be removed together. Its package covers one vent, unlike the two-pack choices, so a multi-vent repair may require more than one kit. Confirm that the pipe and roof opening match before removing the old assembly.

Bottom line: Choose this when you want a single replacement vent kit with sealing materials.

Check Price on Amazon

How to Choose an RV Vent Cap Replacement

Choose by pipe outside diameter and mounting condition: a cap-only replacement works only when its base can be reused. RV plumbing vent stacks commonly use 1- to 2-3/8-inch outside-diameter pipe, but a cap advertised for up to 2 inches may not suit the larger end of that range. Measure the exposed pipe across its widest point, then compare the measurement with the product’s fit. If the roof base is cracked, loose, or missing, select a kit that includes mounting parts rather than assuming a replacement cap will repair the roof connection. Putty tape seals the base-to-roof joint; screws secure the base. A cap does not replace a damaged vent pipe or roof seal.

Cap-Only Parts Versus Full Vent Kits

A cap-only part replaces the cover while retaining a usable roof base; a full kit replaces more of the mounting assembly. Cap-only options can reduce unnecessary work when the base remains sound, while kits with putty tape and screws make sense when the base must be removed. This table separates the common repair paths by the condition of the existing assembly.

Existing condition Part type Check before choosing
Base intact, cap missing Replacement cap Pipe diameter and attachment style
Base damaged or missing Vent kit Pipe range and base footprint
Two vents need covers Two-pack Both pipe measurements

Do not treat a matching pipe diameter as proof that the roof base will fit: mounting footprints and screw locations also matter.

Measuring the Vent Pipe and Roof Base

Measure the pipe’s outside diameter, not its inside opening, because replacement fit ranges are commonly given as O.D. A tape measure or caliper across the pipe gives the relevant dimension; compare that number with the cap’s specified range before purchase. Also measure the old base across its widest dimension and note where the screw holes sit. Several kits here cite a 5.3-inch base, so a different footprint may leave old holes exposed or fail to cover the roof opening. If the old cap is missing, measure the pipe and inspect the roof opening separately rather than estimating the base size from the pipe.

Sealing and Safety During Roof Vent Work

Roof vent work depends on a continuous seal around the base, not just a snug cap over the pipe. Putty tape is used beneath the mounting base, and the base is secured with screws; damaged or compressed sealant can admit water even when the cap fits correctly. Work from a stable ladder on a dry roof, and avoid stepping near unsupported roof edges or fragile panels. Do not block the plumbing vent stack: it allows sewer gases from the waste tanks to escape, and obstructing it can interfere with normal venting. If the surrounding roof membrane is cracked or soft, repair that area before fitting a new cover.

Frequently Asked Questions

How do I measure an RV plumbing vent pipe?

Measure the outside diameter straight across the exposed pipe, rather than the opening inside it. Common RV replacement ranges run from 1 to 2-3/8 inches O.D., so use the actual measurement to choose a compatible cap.

Can I replace only the RV vent cap?

Yes, if the roof base is intact and the new cap attaches to that base or pipe. If the base is cracked or missing, use a full vent kit with mounting parts and reseal the roof joint.

What does putty tape do on an RV vent?

Putty tape seals beneath the vent base where it meets the roof. It does not substitute for securing the base with screws or repairing a damaged roof membrane.

Why does an RV plumbing vent need to stay open?

The vent stack lets sewer gases from the waste tanks escape above the roof. Keep the outlet unobstructed; a cap should protect the pipe without sealing it closed.