Jakel Inc Fan Motor J238: 4 Models Compared by Fit
For a Jakel Inc J238-112-11128, J238-112-11258 or J238-112-11195 replacement, Hiorucet J238-112 inducer motor is the broadest match because it names all three numbers. Choose by the complete motor number and furnace model, since other J238 motors here serve different equipment.
A furnace draft inducer is a blower assembly that moves combustion gases through the vent; because installation involves furnace electrical and combustion components, have a qualified HVAC technician confirm fit and install it.
We earn a commission if you buy through links on this page. As an Amazon Associate I earn from qualifying purchases. Products are compared on manufacturer specifications, not hands-on testing.
- Best overall: Hiorucet J238-112 inducer motor – Names three J238-112 model numbers and multiple Goodman replacement numbers.
- Best for Goodman GMP: Adviace J238-112 inducer blower motor – Lists compatibility with several Goodman GMP furnace models.
- Best for Carrier family: Hiorucet J238-112-11202 assembly – Matches the distinct J238-112-11202 and HC21ZE122A family.
- Best for Rheem/Ruud: Criditpid FB-RFB241 with housing – Names Rheem/Ruud and the J238-150-1533 / J238-150-15165 variants.
| Product | Best for | Jakel model numbers | Assembly | Shop |
|---|---|---|---|---|
| Hiorucet J238-112 inducer motor | Multiple J238-112 models | J238-112-11128, -11258, -11195 | Motor assembly with gasket | Check Price on Amazon |
| Adviace J238-112 inducer blower motor | Goodman GMP furnaces | J238-112-11128, -11258, -11195 | Blower motor | Check Price on Amazon |
| Hiorucet J238-112-11202 assembly | Carrier-family furnaces | J238-112-11202 | Motor and blower wheel assembly | Check Price on Amazon |
| Criditpid FB-RFB241 with housing | Rheem/Ruud equipment | J238-150-1533, J238-150-15165 | Motor with housing | Check Price on Amazon |
Jakel J238 fan motors
Match the complete Jakel number and furnace model before choosing among these inducer assemblies.
Hiorucet J238-112 inducer motor

This option names three J238-112 variants, giving it the broadest match among these motors. The replacement cross-references also include Goodman B1859005 and B1859005S, Fasco A157 and other part numbers. Its purpose is a draft inducer assembly for Goodman furnaces, including Goodman Janitrol and Amana equipment. The package is described as including a gasket. Confirm that the complete number on the existing motor and your furnace model match before selecting it; a similar J238 prefix alone does not establish compatibility.
Bottom line: Choose this when the existing motor is one of the three listed J238-112 variants.
Adviace J238-112 inducer blower motor

Goodman GMP furnace compatibility is the distinguishing point here: the models include GMP075-3, GMP075-4, GMP100-3, GMP100-4 and GMP125-4, as well as GMS80903BNA. The motor cross-references several J238-112 numbers and Goodman B1859005 / B1859005S. This is a different choice from the Carrier-family assembly and Rheem/Ruud assembly below, so use the furnace model and full part number together rather than relying on a shared J238 prefix. The specifications do not establish voltage or included gasket, so confirm those requirements before ordering if they matter to the repair.
Bottom line: Choose it for a Goodman GMP furnace with a matching motor number.
Hiorucet J238-112-11202 assembly

This is the J238-112-11202 branch, not the -11128 / -11258 / -11195 group. It cross-references Carrier, Bryant and Payne HC21ZE122A and HC21ZS122 part numbers, and its motor specification is 115 V, 1.4 FLA, 60 Hz and 3,000 RPM. The assembly includes a blower wheel. Those electrical specifications distinguish it from the other options, whose fields do not give voltage. Do not substitute it for a different J238-112 suffix based only on the shared prefix; verify the furnace and replacement number.
Bottom line: Pick this for equipment matching J238-112-11202 or the Carrier-family numbers.
Criditpid FB-RFB241 with housing

This assembly belongs to the J238-150 family and is identified primarily with Rheem, Ruud and Weather King equipment, unlike the J238-112 Goodman and Carrier-family choices. Its cross-references include Rheem/Ruud 70-24157-03, Fasco 7021-11559 and Ametek 117104-01; the package configuration is specified as with housing. It is relevant only when the old motor carries one of the matching J238-150 numbers or cross-references. A J238 prefix without the remaining digits is not enough to establish fit, so confirm the full number against the furnace before selecting it.
Bottom line: Choose it for a matching Rheem/Ruud J238-150 motor that uses a housing.
How to match a Jakel J238 motor
Match the full motor number, not just the J238 prefix, because the suffix separates different equipment families. Start with the label on the old inducer and compare every digit and hyphen to the replacement number; then cross-check the furnace model. An inducer assembly may include a motor, blower wheel, housing or gasket, and those parts are not interchangeable assumptions. For example, the J238-112-11202 family here is associated with Carrier, Bryant and Payne numbers, while the J238-150 numbers are associated with Rheem/Ruud equipment. If the label is unreadable, have an HVAC technician identify the furnace model and replacement cross-reference before buying. Do not infer fit from appearance or a shared brand name alone.
What a furnace draft inducer does
A draft inducer starts before the burners and establishes airflow through the combustion path and vent. A furnace pressure switch then confirms adequate draft before the ignition sequence can proceed; a failed inducer or blocked vent can therefore prevent a heating cycle. The inducer is not the main circulating blower that moves heated household air through ducts. A replacement must match the furnace’s electrical and mechanical requirements, including motor voltage, mounting, wheel and vent connection. A wrong assembly can cause poor fit or prevent the furnace from proving draft. Because the assembly is part of a combustion appliance and involves line-voltage wiring, power should be isolated before service and installation is best left to a qualified HVAC technician.
J238 suffixes and equipment families
The J238 number families in these choices point to different replacement paths, so the whole suffix matters. Use this table as a first filter, then verify the furnace model and full cross-reference; a family match by itself is not a guarantee of fit.
| Motor number family | Associated equipment or cross-reference | Decision rule |
|---|---|---|
| J238-112-11128 / -11258 / -11195 | Goodman B1859005 / B1859005S and listed Goodman furnaces | Use only when the exact suffix or cross-reference matches |
| J238-112-11202 | Carrier, Bryant, Payne HC21 family | Match the -11202 number or exact HC21 reference |
| J238-150-1533 / -15165 | Rheem/Ruud and listed Fasco/Ametek references | Match the J238-150 suffix and housing configuration |
When a furnace model or old motor number conflicts with the proposed replacement cross-reference, stop and confirm the application rather than treating the table as permission to substitute.
Safe inducer replacement checks
Furnace inducer work combines electrical wiring with combustion venting, so a qualified technician should perform the replacement and verify operation afterward. The technician should confirm the vent path is clear, the wheel turns freely, the assembly seals correctly, and the pressure switch proves draft during a heating call. A pressure-switch fault is not automatically a bad motor: blocked venting, condensate problems on condensing equipment or damaged tubing can produce a similar symptom. Shut off furnace power before any access, and do not bypass a safety switch to test operation. After the repair, the furnace should complete its normal ignition sequence without unusual noise or vent leakage; persistent faults call for diagnosis rather than repeated resets.
Frequently Asked Questions
What does the J238 suffix tell me?
The suffix distinguishes motor families and replacement applications. For example, J238-112-11202 is a different match from J238-112-11128, so compare the entire number rather than only the J238 prefix.
Can I use any J238 inducer motor?
No; match the full part number and furnace model. J238-112 and J238-150 variants in these choices correspond to different equipment and cross-reference families.
Is the inducer the same as the furnace blower?
No; the inducer moves combustion gases through the vent, while the main blower circulates household air through the ducts. The pressure switch uses draft proving as part of the burner safety sequence.
Should I replace a pressure switch with the inducer?
Not without diagnosis: a blocked vent, condensate issue or damaged pressure tubing can also prevent draft proving. A technician should inspect the vent path and test the switch circuit rather than bypassing the safety.
Can I install a furnace inducer motor myself?
Inducer replacement involves line-voltage wiring and the combustion vent path, so qualified HVAC service is the safer choice. Power must be isolated before access, and operation should be verified through a complete ignition cycle afterward.