Onan 4000 Generator Fuel Pump Kits Compared by Parts

For an Onan 4000 generator fuel pump replacement, LIDSCURA 149-2311 Pump Kit is the closest match if you want the pump, fuel filter, hose and clamps together. Choose a different kit if you also need an air filter or want the pump-and-filter combination without the extra air-filter part.

These are aftermarket replacement kits for compatible Onan/Cummins MicroQuiet and Microlite generators; check your generator model and existing part numbers before ordering.

We earn a commission if you buy through links on this page. As an Amazon Associate I earn from qualifying purchases. Products are compared on manufacturer specifications, not hands-on testing.

Product Best for Included filters Fuel line and clamps Fitment range Shop
LIDSCURA 149-2311 Pump Kit Fuel-side replacement 149-2457 fuel filter Fuel hose; 4 clamps MicroQuiet 3600/4000; QG RV Check Price on Amazon
partszen 149-2311 Pump Tune-Up Kit Air-filter service 149-2457 fuel; 140-3280 air Fuel line; 4 clamps MicroQuiet 3600/4000; QG RV Check Price on Amazon
CNRAQR 149-2311 Pump and Filter Pump and filter 149-2457 fuel filter — MicroQuiet 3600/4000; QG RV Check Price on Amazon
KAKATHU 149-2311 Tune-Up Kit KY series service 149-2457 fuel; 140-3280 air Fuel line; 4 clamps KY/MicroQuiet 3600W and 4000W Check Price on Amazon

Onan 4000 generator fuel pump kits

Compare the part numbers, included service parts and stated generator fitment before choosing a replacement kit.

LIDSCURA 149-2311 Pump Kit

LIDSCURA 149-2311 Pump Kit

LIDSCURA 149-2311 Pump Kit is a fuel-side kit centered on the 149-2311 pump and 149-2457 filter, with a hose and four clamps included. Its compatibility covers Camp Power KYD, MicroLite KY, MicroQuiet KY, QG RV, Microlite RV QG, and Onan MicroQuiet 3600 and 4000 generator models. The combination suits a replacement where those fuel-side parts are the goal, rather than a broader tune-up with an air filter. Confirm the part numbers on your existing components and the exact generator model before selecting this kit, since the model family names cover multiple configurations.

Bottom line: Choose this when you need the fuel pump, fuel filter and installation hose-and-clamp set.

Check Price on Amazon

partszen 149-2311 Pump Tune-Up Kit

partszen 149-2311 Pump Tune-Up Kit

partszen 149-2311 Pump Tune-Up Kit adds an air filter to the 149-2311 pump and 149-2457 fuel filter, making it the broader service set among these choices. The package also includes a fuel line and four clamps, and the air-filter replacement number is 140-3280, also cross-referenced as 48-2017. Fitment is given for KYD, MicroLite KY, MicroQuiet KY, QG RV, Microlite RV QG, and Onan 3600/4000 models. This kit suits maintenance that includes both intake-air and fuel filtration; if you only need fuel-side parts, the extra air filter may be unnecessary. Verify the air-filter number as well as the pump number.

Bottom line: Pick this for a combined fuel-pump and air-filter service.

Check Price on Amazon

CNRAQR 149-2311 Pump and Filter

CNRAQR 149-2311 Pump and Filter

CNRAQR 149-2311 Pump and Filter focuses on the 149-2311 pump and 149-2457 fuel filter rather than advertising an air-filter replacement, which keeps the named service scope centered on fuel delivery and filtration. Its fitment includes Camp Power KYD, MicroLite KY, MicroQuiet KY, QG RV, Microlite RV QG, and Onan MicroQuiet 3600 and 4000 models. The kit may suit owners matching those model families who need both fuel-side components. Unlike some alternatives here, its package description does not identify a hose or clamps, so check whether you already have the needed connection hardware before starting the repair.

Bottom line: Choose this when the pump and fuel filter are the parts you need.

Check Price on Amazon

KAKATHU 149-2311 Tune-Up Kit

KAKATHU 149-2311 Tune-Up Kit

KAKATHU 149-2311 Tune-Up Kit names the KY and MicroQuiet/Microlite series explicitly, including 3600W (3.6KY) and 4000W (4KY) gasoline generator models. Its set contains the 149-2311 pump, 149-2457 fuel filter, 140-3280 air filter, fuel line and four clamps, so it covers more routine service items than a pump-and-fuel-filter-only combination. The narrower model wording can help buyers matching a KY-series unit, but it does not spell out the same wider QG RV fitment range named by some alternatives. Match your generator and part numbers before purchase if your unit is identified by a QG RV designation.

Bottom line: Pick this when your generator is a named KY or MicroQuiet/Microlite model.

Check Price on Amazon

How to choose an Onan 4000 generator fuel pump

Start with the pump part number and generator model, not the 4000-watt label alone. The kits here cross-reference 149-2311 and aliases including E11007, A029F889, and 149-2311-01/-02; the fuel filter number is 149-2457. A 4000W rating identifies output class, but it does not by itself establish that a pump or filter fits a specific generator configuration. If routine service also calls for an air filter, compare kits that include 140-3280/48-2017; otherwise, a fuel-side set avoids adding that part. Use the generator data plate and the part number on the old component to narrow the match. When those identifiers disagree, resolve fitment before ordering rather than assuming the wattage is enough.

Fuel-only kits versus tune-up kits

Fuel-only sets pair the pump with a fuel filter, while tune-up kits can add air filtration and connection pieces. A fuel filter protects the fuel system from debris; the air filter serves the engine intake, so the two filters do different jobs and are not interchangeable. For a pump replacement alone, compare whether the kit includes a hose and clamps, since those components can be useful if the existing line or clamps need replacement. For a broader service, an air-filter part number is an important distinction. This table maps the kit contents to common maintenance needs.

Maintenance need Kit contents to prioritize Part numbers to match
Fuel-side replacement Pump, fuel filter, line and clamps 149-2311; 149-2457
Fuel and intake service Pump, fuel and air filters, line and clamps 149-2311; 149-2457; 140-3280

Generator fit and part-number checks

Onan/Cummins MicroQuiet and Microlite names cover more than one generator size, so confirm the specific model designation before treating a family name as a fit guarantee. The sets describe coverage including 3600 and 4000 models, and some name KYD, MicroLite KY, MicroQuiet KY, or QG RV separately. Compare all available identifiers: the generator model, pump number, and filter numbers. If the old pump has a 149-2311 cross-reference but your unit’s model falls outside the families, confirm the fit range before ordering. A part-number match is more useful than comparing only the 3.6 or 4 kW output class.

Fuel-system replacement safety

Gasoline is highly flammable, so work on a generator fuel system only with the engine off and fully cool, away from flames, sparks and smoking. Shut off the fuel supply where the system provides a valve, and contain drained fuel in an approved gasoline container rather than an open tray. Fuel lines can retain fuel after shutdown; avoid spilling fuel on hot engine or exhaust parts. After assembly, inspect the connections for leaks before running the generator, and stop immediately if fuel is present outside the line. Use the generator service procedure for the exact model when opening the system, because access and shutoff arrangements differ among RV generator installations.

Frequently Asked Questions

What part number does an Onan 4000 fuel pump use?

The pump number in these replacement kits is 149-2311, with cross-references including E11007 and A029F889. Compare the number on the installed pump and the generator model before selecting a replacement.

Is 149-2457 the fuel filter number?

Yes, 149-2457 is the fuel-filter number paired with the pump in these kits. Some kits also include a separate 140-3280 air filter, which serves the intake rather than the fuel system.

Does every pump kit include a fuel hose?

No; package contents differ across these options. Some include a fuel line and four clamps, so check the kit contents if your existing hose or clamps need replacement.

Can a 4000-watt Onan pump fit a 3600-watt generator?

The compatibility claims for these kits include MicroQuiet 3600 and 4000 generator models. Confirm the model family and pump part number, since output rating alone does not verify fit.

How should I check for fuel leaks after replacing a pump?

Inspect every connection for wetness or fuel odor before operating the generator, and do not run it if a leak is present. Keep the engine cool and eliminate ignition sources while working around gasoline.