Outside Gas Fireplace Vent Cover: Fit and Types Compared
For a trapezoid termination cap, Draft Decor #2 Trapezoid Cover is the closest match; the deciding factor is the cap’s shape and dimensions. Direct-vent fireplace covers shield exterior terminations, but choose a different model if your cap is square or a Lennox SV 4.5 HT-2.
Measure the cap before choosing: these covers are made for particular shapes and sizes, not as universal fits.
We earn a commission if you buy through links on this page. As an Amazon Associate I earn from qualifying purchases. Products are compared on manufacturer specifications, not hands-on testing.
- Best overall: Draft Decor #2 Trapezoid Cover – Its full cover top and foam insert are designed for a trapezoid-shaped termination cap or shroud.
- Best for square caps: Draft Decor #1 Square Cover – It is made for a specific-size DirectVent square horizontal termination cap.
- Best for Lennox HT-2: Draft Decor #3 Lennox HT-2 Cover – It fits the Lennox SV 4.5 HT-2 termination cap and has an adjustable top.
| Product | Best for | Designed fit | Cover dimensions | Shop |
|---|---|---|---|---|
| Draft Decor #2 Trapezoid Cover | Trapezoid caps | Trapezoid cap or shroud | 13.5 × 10.5 × 8 in | Check Price on Amazon |
| Draft Decor #1 Square Cover | Square caps | Specific-size DirectVent square cap | 13 × 13 × 8 in | Check Price on Amazon |
| Draft Decor #3 Lennox HT-2 Cover | Lennox HT-2 | Lennox SV 4.5 HT-2 | 7 × 14 × 16 in | Check Price on Amazon |
Outside Gas Fireplace Vent Covers
Match the termination cap’s shape and measurements before choosing a cover or replacement cap.
Draft Decor #2 Trapezoid Cover

For a trapezoid-shaped termination cap or shroud, this cover has a full top designed to accommodate different top vent designs. Its ½-inch polystyrene insert fits over the bottom screen area, and soft twist ties secure the cover. The maker says its approximately 6.5-mil, double-sided aluminum barrier reflects 97% of radiant heat. At 13½ inches high, 10½ inches wide, and 8 inches deep, the measurements are central to fit; this is not a universal cover. Choose it only after checking your cap or shroud dimensions and shape.
Bottom line: Choose this when your termination cap or shroud is trapezoid-shaped and matches the cover measurements.
Draft Decor #1 Square Cover

Unlike the trapezoid cover, this model targets a specific-size DirectVent square horizontal termination cap. Four soft ties hold it in place, and a ½-inch foam lining helps protect the front from wear at sharp corners. The maker says the approximately 6.5-mil aluminum barrier reflects 97% of radiant heat. Its dimensions are 13 inches long, 13 inches wide, and 8 inches high. Coverage has a limit: the cover reaches the vent openings but not the cap edge or mount, so buyers needing edge coverage should consider that before choosing it.
Bottom line: Choose this for a matching square DirectVent cap when coverage of the cap edge is not required.
Draft Decor #3 Lennox HT-2 Cover

This cover is specific to the Lennox SV 4.5 HT-2 horizontal termination cap, unlike the square and trapezoid options. Two soft ties secure it, a ½-inch foam insert closes the bottom screen area, and three bungee cords adjust the top for different vent designs. The maker says the material is Class A/Class 1 fire rated and not affected by moisture or humidity. The fit is narrow: the product dimensions are 7 inches long, 14 inches wide, and 16 inches high, and the maker warns against using it on other sizes. Do not operate the fireplace or pilot while the cover is on.
Bottom line: Choose this only for the specified Lennox SV 4.5 HT-2 termination cap.
How to Choose an Outside Gas Fireplace Vent Cover
Start with the termination cap’s shape and exact dimensions; a cover meant for a square cap will not automatically fit a trapezoid cap. Measure width, height, and projection from the wall, then compare those measurements with the cover’s dimensions. Also identify whether you need a seasonal shield over a termination cap or a replacement termination cap: those are different products. If any measured side differs from the intended fit, do not assume the ties or adjustable top will make up the difference. Gas fireplace terminations are part of the venting system, so use a cover only when the fireplace is off and remove it before operating the appliance.
Termination Cap Shapes and Coverage
Square, trapezoid, and model-specific termination caps call for different cover shapes and attachment points. A full-top cover designed for a trapezoid shroud differs from a square cover that protects the vent openings but leaves the cap edge and mount exposed. A model-specific cover may also use an adjustable top to accommodate deflector designs, but that does not make it universal. Before choosing, check where the cover closes the opening and whether it covers the area you intend to shield. Never block or cover a termination while the fireplace or pilot is operating; venting must remain unobstructed during use.
The distinction between a cover and a cap matters as much as the shape. A steel termination cap is a vent component; it is not necessarily an over-cover for an installed cap.
Measurements and Vent-System Fit
Match both the exterior cap dimensions and the vent connection size when selecting a termination part. A common direct-vent size designation such as 4 × 6⅝ inches refers to the vent system’s inner and outer pipe diameters, not the outside width of its wall cap. Exterior dimensions can be much larger because a termination includes a square hood, deflector, and mounting flange. Measure the existing cap’s height, width, and depth, and check its model marking where available. If you cannot confirm the existing termination’s model or vent size, verify compatibility with the fireplace manufacturer before installing a replacement.
Cover or Replacement Cap
Use a protective cover only when the fireplace is shut down; remove it before lighting the appliance or pilot. A termination cap, by contrast, remains part of the vent arrangement and must match the appliance’s approved vent system. The table separates these jobs so you can narrow the type before comparing dimensions.
| Need | Product type | Fit check |
|---|---|---|
| Shield an existing termination | Over-cover | Shape and outside dimensions |
| Replace an existing termination | Vent cap | Vent system size and appliance compatibility |
Frequently Asked Questions
Can a gas fireplace run with its vent cover on?
No; remove a protective cover before operating the fireplace or pilot. An obstructed termination can interfere with venting, so keep the outlet clear during use.
How do I measure an exterior fireplace vent cap?
Measure the cap’s width, height, and projection from the wall in inches, including any deflector or shroud the cover must pass over. Compare all three dimensions with the intended cover rather than relying on the vent-pipe size alone.
What does a 4 by 6⅝ vent size mean?
It refers to the vent system’s nominal inner and outer pipe diameters, not the exterior dimensions of the termination hood. The outside cap can be substantially wider and taller than the pipe.
Can a square vent cover fit a trapezoid cap?
Do not assume it will; cover shapes are designed around particular termination shapes and attachment points. Choose by matching the existing cap’s shape and measurements.
Is a fireplace vent cover the same as a termination cap?
No; a protective cover fits over or closes a termination while the appliance is off, while a termination cap is a vent component. A replacement cap must match the fireplace’s vent system.