AC Unit Fan Relay: 5 Models Compared by Fit
For an AC unit fan relay, APFR-380 90-980 24V SPST Relay is the closest match when you need a 24V HVAC isolation relay with an included universal bracket. Supco 90370 24V SPDT Relay differs with SPDT contacts, while Dreyoo 90-380 24V SPST Relay and FrigeSwift 90380 24V 2-Pack provide coil and load ratings to compare against the equipment requirements.
A fan relay is an electrically operated switch that lets a low-voltage control circuit switch a separate load circuit; confirm the existing relay’s coil voltage, contact form, and load rating before replacing it.
We earn a commission if you buy through links on this page. As an Amazon Associate I earn from qualifying purchases. Products are compared on manufacturer specifications, not hands-on testing.
- Best overall: APFR-380 90-980 24V SPST Relay – A 24V heavy-duty SPST isolation relay with a universal bracket.
- Best for rating checks: Dreyoo 90-380 24V SPST Relay – Provides coil frequency and load ratings at three voltages.
- Best for two relays: FrigeSwift 90380 24V 2-Pack – A two-pack with 24V AC coil and load ratings.
| Product | Best for | Coil | Contacts | Pack | Shop |
|---|---|---|---|---|---|
| APFR-380 90-980 24V SPST Relay | Bracket-equipped replacement | 24V AC | SPST | 1 relay | Check Price on Amazon |
| Dreyoo 90-380 24V SPST Relay | Published load ratings | 24VAC, 50/60Hz | SPST, 6 terminals | 1 relay | Check Price on Amazon |
| 2-Pack 24V SPST Fan Relay | Two-relay supply | Typically 24V | SPST | 2 relays | Check Price on Amazon |
| FrigeSwift 90380 24V 2-Pack | Rated two-pack | 24V AC, 50/60Hz | Normally open/closed | 2 relays | Check Price on Amazon |
| Supco 90370 24V SPDT Relay | SPDT contact option | 24V coil | SPDT, 1 NO/1 NC | 1 relay | Check Price on Amazon |
AC Unit Fan Relays
Compare coil voltage, contact arrangement, and package quantity before selecting a relay for the control circuit.
APFR-380 90-980 24V SPST Relay

APFR-380 90-980 24V SPST Relay is the only option here whose name specifies a universal mounting bracket, which can help when the replacement needs a bracketed installation. It is a 24V AC, single-pole single-throw isolation relay presented for HVAC blowers, humidifiers, and heat sequencers. Its dimensions are 3.0 inches high, 2.8 inches long, and 1.5 inches wide, useful when checking cabinet clearance. The tradeoff is that the maker gives no contact load rating, so this choice is less suitable when the equipment label calls for verifying amperage capacity before installation.
Bottom line: Choose this when a universal bracket and SPST switching match the existing setup.
Dreyoo 90-380 24V SPST Relay

Dreyoo 90-380 24V SPST Relay separates itself with explicit load figures: 12 FLA/60 LRA at 125VAC, 8 FLA/48 LRA at 250VAC, and 18A resistive at 277VAC. The coil is 24VAC at 50/60Hz, and six quick-connect terminals suit a compatible SPST wiring layout. The manufacturer identifies UL certification and use with HVAC blower, humidifier, and heat-sequencer applications. This is a practical candidate when the equipment’s electrical requirements can be matched against those figures; its one-relay pack is not the choice for someone seeking a spare in the same package.
Bottom line: Choose this when its published coil and contact ratings match the unit.
2-Pack 24V SPST Fan Relay

2-Pack 24V SPST Fan Relay stands out as a two-relay pack identified for 90-980 isolation service and fan-control applications. The maker describes low-voltage triggering, typically 24 volts, and names HVAC, Coleman furnace, Goodman blower, and humidifier uses. It also describes metal construction with resistance to wear and corrosion. The compatibility wording spans many equipment types, but this option lacks a precise contact load rating in the facts; skip it if the replacement decision depends on confirming a specific amperage limit. Check the existing coil and terminal layout before installation.
Bottom line: Choose this when two compatible SPST relays are needed and load ratings are confirmed.
FrigeSwift 90380 24V 2-Pack

FrigeSwift 90380 24V 2-Pack is the other two-relay option, and its features provide 24V AC coil frequency plus load ratings: 12 FLA/60 LRA at 125VAC and 8 FLA/48 LRA at 250VAC. The name identifies normally open/normally closed contacts, unlike the single-throw options. The manufacturer describes a plastic case, copper coils, metal components, and operation up to 65°C. Use the contact diagram on the existing relay to confirm the required switching arrangement, since choosing normally open versus normally closed incorrectly can leave the fan circuit behaving differently than intended.
Bottom line: Choose this when the wiring requires the contact arrangement and a two-pack.
Supco 90370 24V SPDT Relay

Supco 90370 24V SPDT Relay differs from the SPST choices by offering single-pole double-throw contacts, including one normally open and one normally closed contact. Its load current is 12A, and the relay has a sealed enclosure. Those features make it relevant when the control circuit specifically calls for an SPDT relay rather than a simple on/off SPST switch. The facts do not give an AC coil frequency or a voltage-specific FLA/LRA breakdown, so a buyer who needs those ratings should confirm them against the unit’s wiring diagram before selecting this model.
Bottom line: Choose this when the circuit calls for SPDT contacts and the 12A rating fits.
How to Match an AC Unit Fan Relay
Match the relay coil voltage and contact arrangement before comparing package count or dimensions. HVAC control circuits commonly use a 24VAC transformer, while relay contacts switch a separate load; the printed coil rating must match the control voltage. SPST provides one switched path, whereas SPDT selects between normally open and normally closed paths. A relay marked 24VAC is not automatically interchangeable with every 24V relay: terminal position and contact form matter. Read the wiring diagram or the old relay’s markings, then compare its coil, contact form, and load rating. If the system label specifies a load rating, do not substitute a relay without a compatible rating.
SPST and SPDT Contacts Compared
SPST suits a circuit that needs one on/off switching path; SPDT suits a circuit that must switch between two contact states. “Normally open” means the contact is open while the coil is de-energized, and “normally closed” means that contact is closed in that state. The relay’s diagram defines these states, not the fan’s operating state in every system. Use this comparison to identify the needed contact type before choosing among the options.
| Contact type | Switch paths | Use when |
|---|---|---|
| SPST | One | The circuit needs a single switched path |
| SPDT | Two contact choices | The circuit needs NO and NC paths |
When the old relay has both NO and NC terminals wired, an SPST replacement is not an equivalent substitute.
Check Load Ratings and Installation Space
Match the contact rating to the motor or other switched load, not just to the 24V coil. Motor starting current can be higher than running current, which is why relay specifications may separate FLA (full-load amps) from LRA (locked-rotor amps); compare the applicable voltage and both values where provided. A resistive rating is not a motor rating. Also measure the available mounting area: a relay that is electrically compatible can still conflict with adjacent wiring or a cabinet wall. Disconnect power before working inside HVAC equipment, and have a qualified technician handle wiring if you cannot safely identify the control and load terminals.
Relay Replacement Mistakes to Avoid
The most common mismatch is treating coil voltage and contact capacity as the same specification. The coil is the control side; contact ratings govern the circuit being switched. Another mistake is relying on a broad equipment compatibility claim instead of checking the original relay’s part marking, contact diagram, and connected terminal positions. Photographing the existing wiring before disconnecting anything can help preserve terminal mapping, but it does not replace a wiring diagram. Never bypass a relay to keep a fan running: that can defeat the equipment’s intended control sequence and create an electrical hazard.
Frequently Asked Questions
What does a 24V AC fan relay do?
A 24V AC fan relay uses a low-voltage coil to operate contacts in a separate circuit. The coil rating must match the control circuit, while the contacts must be rated for the switched load.
How can I tell whether my relay is SPST or SPDT?
Check the relay’s terminal diagram or markings: SPST has one switched path, while SPDT provides normally open and normally closed contact choices. If both NO and NC terminals are wired, do not replace it with SPST.
What do FLA and LRA mean on a relay?
FLA is full-load amps and LRA is locked-rotor amps, a motor’s high starting condition. Compare the figures at the voltage used by the equipment; a resistive-amp rating does not establish motor capacity.
Can I replace a 24V relay with any other 24V relay?
No; the coil voltage alone is not enough to establish compatibility. Match the contact form, terminal layout, and load rating as well, especially when the fan motor has a high starting current.
Is it safe to replace an AC fan relay myself?
Only work on HVAC wiring with power disconnected and the correct wiring diagram available. HVAC equipment can contain line-voltage circuits alongside 24V controls, so use a qualified technician if you cannot identify and isolate both safely.