Well Pump Start Capacitors: Match by MFD and Horsepower

For a well pump control box, choose the start capacitor by matching its MFD range and box model; BMI 105–126 MFD Capacitor fits compatible Franklin 1, 1.5 and 2 HP boxes. Choose a different option when your box calls for another capacitance range or horsepower.

A start capacitor briefly helps a motor start, and is not interchangeable with a run capacitor.

We earn a commission if you buy through links on this page. As an Amazon Associate I earn from qualifying purchases. Products are compared on manufacturer specifications, not hands-on testing.

Product Best for Capacitance Voltage Compatible pump size Shop
BMI 105–126 MFD Capacitor 1–2 HP boxes 105–126 MFD 220 VAC 1–2 HP Check Price on Amazon
105–126 MFD Capacitor, 2-Pack Two-capacitor supply 105–126 MFD 220–250 VAC 1–2 HP Check Price on Amazon
BMI 86–103 MFD Capacitor Lower-MFD boxes 86–103 MFD 220 VAC 3/4–1 HP Check Price on Amazon
BMI 59–71 MFD Capacitor Low-MFD boxes 59–71 MFD 220 VAC 1/2–3/4 HP Check Price on Amazon

Well Pump Start Capacitors

Match the capacitor’s capacitance and control-box model to the pump system before selecting a replacement.

BMI 105–126 MFD Capacitor

BMI 105–126 MFD Capacitor

BMI 105–126 MFD Capacitor covers the broadest pump range among these single-capacitance options, with a 105–126 MFD rating for compatible 1, 1.5 and 2 HP Franklin control boxes. Its compatible box models include 2823008110 and 2823018110, and it replaces Franklin part 275464113. BMI says the capacitor is made in the USA. The 220 VAC rating and 2.15-inch width suit a buyer replacing the same style and rating; this is not a fit for lower-MFD boxes simply because the horsepower overlaps.

Bottom line: Choose it for a compatible 1–2 HP box requiring 105–126 MFD.

Check Price on Amazon

105–126 MFD Capacitor, 2-Pack

105–126 MFD Capacitor, 2-Pack

Unlike BMI 105–126 MFD Capacitor, 105–126 MFD Capacitor, 2-Pack supplies two capacitors, each rated 105–126 MFD and 220–250 VAC. The maker identifies compatibility with Franklin 1, 1.5 and 2 HP control boxes, including models 2823008110 and 2823018110, and cites replacement part 275464113. Each capacitor measures 3.35 inches high by 1.43 inches in diameter, a useful dimension check for a compact control box. The maker identifies this as a non-original replacement, so buyers needing an original part should select accordingly.

Bottom line: Choose it when you need a compatible 105–126 MFD replacement in a two-pack.

Check Price on Amazon

BMI 86–103 MFD Capacitor

BMI 86–103 MFD Capacitor

BMI 86–103 MFD Capacitor uses a lower 86–103 MFD range than the 105–126 MFD options, making the box’s required rating the deciding factor. It is intended for compatible Franklin 3/4 and 1 HP boxes, including 2801074915, plus CRC 2824085015 and Tuhorse TCB15M230; it replaces Franklin part 275464118. BMI says it is made in the USA. Its 220 VAC, 50/60 Hz rating is for a specific control-box application, so a 1 HP pump alone does not establish a match.

Bottom line: Choose it for compatible 3/4–1 HP boxes calling for 86–103 MFD.

Check Price on Amazon

BMI 59–71 MFD Capacitor

BMI 59–71 MFD Capacitor

BMI 59–71 MFD Capacitor has the lowest capacitance range in this group: 59–71 MFD at 220 VAC and 50/60 Hz. It is intended for compatible Franklin 1/2 and 3/4 HP boxes, including 2801054915, and CRC 2824075015; the compatible Franklin replacement part is 275464105. BMI says it is made in the USA. This range differs from BMI 86–103 MFD Capacitor even though both include 3/4 HP applications, so use the control-box requirement rather than horsepower alone to choose between them.

Bottom line: Choose it for a compatible 1/2–3/4 HP box requiring 59–71 MFD.

Check Price on Amazon

How to choose a well pump start capacitor

Match the microfarad range and voltage printed on the existing capacitor or control-box diagram before using horsepower as a filter. Start capacitors provide a brief starting boost; run capacitors, where used, remain in circuit during operation and have a different duty. These options have 220 VAC or 220–250 VAC ratings, so the system voltage and the control-box requirement must agree. For example, a 3/4 HP rating appears in both the 59–71 and 86–103 MFD applications here, making capacitance and box model—not horsepower alone—the deciding test.

Disconnect power before opening a control box. Capacitors can retain a dangerous electrical charge after power is off; servicing should be done only by someone qualified to safely isolate and discharge the circuit.

Control-box fit and capacitor dimensions

Control-box model numbers are a more precise fit check than pump horsepower alone. Verify the full model number against the compatible-model range before installing a replacement; small variations in a box series can change its electrical parts. Physical clearance matters too: 105–126 MFD Capacitor, 2-Pack measures 3.35 inches tall and 1.43 inches in diameter, while BMI 105–126 MFD Capacitor, BMI 86–103 MFD Capacitor and BMI 59–71 MFD Capacitor list a 3.35-inch height and 2.15-inch length and width. Measure the existing component and available space when the enclosure is tight.

Capacitor terminals and wiring must also match the circuit layout. Photographing wiring before removal can help a qualified repairer preserve connections, but never handle terminals until power isolation and safe discharge are confirmed.

Capacitance ranges compared

The ranges separate the options more clearly than their overlapping horsepower labels. Use the required MFD range on the old part or the control-box diagram to narrow the choice, then confirm the compatible box model and voltage. MFD and µF are two notations for the same capacitance unit.

Required range Application in this group Decision cue
59–71 MFD Compatible 1/2–3/4 HP boxes Match the lower range
86–103 MFD Compatible 3/4–1 HP boxes Do not substitute by horsepower alone
105–126 MFD Compatible 1–2 HP boxes Check the precise box model

A capacitor with the same horsepower description but a different MFD range is not an equivalent choice. If the existing rating is unreadable, confirm the control-box model before ordering.

Replacing a well pump start capacitor safely

Capacitor replacement involves electrical hazards even in a small control box. Turn off and lock out the circuit at its source, verify absence of voltage with an appropriate meter, and have a qualified person safely discharge the capacitor before touching terminals. Do not rely on a switch alone or assume a capacitor has discharged on its own.

After safe isolation, replacement should preserve the original wiring and use a part matching the specified capacitance, voltage and physical fit. A bulging, leaking or burned capacitor can point to a wider motor or control-box fault, so replacing only the visible part may not resolve repeated failure. Stop if wiring, ratings or damage are unclear and use a pump technician.

Frequently Asked Questions

What does MFD mean on a pump capacitor?

MFD means microfarads, the capacitance value that indicates how much electrical charge a capacitor can store. A start capacitor must match the MFD range required by the control box.

Can I use a higher MFD capacitor in my well pump?

No—use the MFD range specified for the control box rather than choosing a higher value. The ranges here are 59–71, 86–103 and 105–126 MFD, and overlapping horsepower labels do not make them interchangeable.

How can I tell if a pump capacitor is a start type?

Check the control-box wiring diagram and the capacitor’s specified role, not just its shape. Start capacitors provide a brief starting boost, while run capacitors are designed for continuous operation.

Can a well pump capacitor shock you when power is off?

Yes, a capacitor can retain a dangerous charge after the circuit is switched off. Power must be isolated, absence of voltage verified, and the capacitor safely discharged by a qualified person before handling.

What measurements should I check before replacing one?

Check the MFD range, voltage rating, control-box model and physical dimensions. For example, the 2-pack option measures 3.35 inches tall by 1.43 inches in diameter, which may not fit a box sized for a wider component.