RV GFCI Outlet Replacement: 3 Options Compared

For an RV GFCI outlet replacement, RV Designer S807 Dual GFCI is the clearest match when the existing circuit is 125V AC and protected at 15A or 20A. Choose a different option if you need a two-pack or a surface-mount extension box.

A GFCI receptacle monitors current imbalance and interrupts power during a ground fault; before replacing one, disconnect shore power and turn off the generator and inverter.

We earn a commission if you buy through links on this page. As an Amazon Associate I earn from qualifying purchases. Products are compared on manufacturer specifications, not hands-on testing.

  • Best overall: RV Designer S807 Dual GFCI – Its cover plate and fasteners are included, and it is specified for 125V AC RV circuits protected at 15A or 20A.
  • Best for two outlets: RVINGPRO 15A GFCI, 2-Pack – The package includes two 15A, 125V receptacles with decorator wall plates and screws.
  • Best for surface mounting: ProCamp 15A Self-Test GFCI Kit – The kit includes a surface-mount extension box as well as the receptacle and wall plate.
Product Best for Pack Mounting parts Shop
RV Designer S807 Dual GFCI Direct RV replacement 1 Cover plate; fasteners Check Price on Amazon
RVINGPRO 15A GFCI, 2-Pack Two replacements 2 Decorator plates; screws Check Price on Amazon
ProCamp 15A Self-Test GFCI Kit Surface mounting — Wall plate; extension box Check Price on Amazon

RV GFCI Outlet Replacement Options

Match the receptacle rating and mounting style to the existing RV installation before choosing a replacement.

RV Designer S807 Dual GFCI

RV Designer S807 Dual GFCI

RV Designer S807 Dual GFCI is the only option here explicitly specified for 15A or 20A overcurrent-protected RV circuits. The black dual-outlet receptacle is 6.56 inches long, 3.69 inches wide, and 1.63 inches high, with a cover plate and fasteners included. The maker identifies it as UL Listed and for grounded two-wire branch circuits. Its circuit range makes it a fit only when the existing circuit matches; it is not a universal replacement for every RV receptacle. Confirm the circuit protection and the available mounting space before ordering.

Bottom line: Choose this when the existing RV circuit is 125V AC and protected at 15A or 20A.

Check Price on Amazon

RVINGPRO 15A GFCI, 2-Pack

RVINGPRO 15A GFCI, 2-Pack

RVINGPRO 15A GFCI, 2-Pack stands out as the only two-pack, useful when replacing two compatible receptacles. Each white duplex unit is 15A, 125V, and 60 Hz; decorator wall plates and screws are included. The maker says the receptacle meets UL 943 Class A and UL 498 standards and has status indicators for power and protection, with an automatic self-test. Those indicators add a visual status check, but they do not replace verifying correct installation with the receptacle’s test and reset controls. This option is limited to a 15A circuit match, so check the existing circuit rating before selecting it.

Bottom line: Choose this if you need two 15A, 125V receptacles and matching plates.

Check Price on Amazon

ProCamp 15A Self-Test GFCI Kit

ProCamp 15A Self-Test GFCI Kit

ProCamp 15A Self-Test GFCI Kit is the surface-mount choice because its kit includes an extension box along with the white 15A/125V receptacle and screw-on wall plate. The maker describes the outlet as self-monitoring, tamper-resistant, and suitable for residential and RV use; an LED indicates status. The box can help where a recessed receptacle setup is unsuitable, but its presence does not establish that the kit will fit every RV wall or enclosure. Check the available space and mounting arrangement, as well as the circuit rating, before replacing the existing outlet.

Bottom line: Choose this when the RV installation needs a surface-mount box.

Check Price on Amazon

How to choose an RV GFCI outlet replacement

Match the replacement’s voltage and amperage to the existing circuit before comparing extras. The RV Designer option is specified for 125V AC circuits protected at either 15A or 20A; the other RV-suitable choices are 15A receptacles. A receptacle’s face and included plate do not prove its wiring or rating will suit your circuit. Check the old device markings and the circuit breaker rating, and confirm the receptacle’s physical dimensions and mounting style against the opening. If the circuit rating is unclear, stop and ask a qualified RV technician or electrician rather than guessing. A GFCI protects against ground-fault current; it does not replace correct overcurrent protection or proper grounding.

RV GFCI mounting and fit

Mounting style determines whether an outlet can fit the existing opening without changing the enclosure. A cover plate and fasteners suit a compatible existing installation; an extension box is a distinct option for surface mounting. Measure the opening and available depth before choosing, because receptacle dimensions alone do not account for wire bend space or the surrounding wall. The S807 measures 6.56 by 3.69 by 1.63 inches, while the other two products do not provide dimensions here. For installations with under 1.63 inches of available depth, do not assume the S807 will fit; verify the required clearance and enclosure before ordering. Keep the receptacle accessible for testing and resetting.

Safe replacement and wiring checks

Disconnect every power source before opening an RV receptacle enclosure: unplug shore power, switch off the generator, and disable the inverter. Turn off the relevant breaker and use a properly rated voltage tester to verify the conductors are de-energized; a breaker label alone is not proof. GFCI receptacles have LINE terminals for incoming power and LOAD terminals when protecting downstream outlets, so preserve the existing arrangement only after identifying the conductors. A mistaken LINE/LOAD connection can leave the receptacle or downstream protection inoperative. After installation, use the built-in test and reset controls and check any protected downstream outlets. If the wiring, grounding, or source configuration is uncertain, have a qualified technician perform the replacement.

GFCI test buttons and status indicators

Use the receptacle’s TEST and RESET controls to check operation after installation and periodically thereafter; a status light is a helpful indicator, not a substitute for the functional test. GFCI receptacles monitor for a difference between outgoing and returning current and trip when leakage reaches a hazardous level, commonly around 4 to 6 milliamps for Class A devices. A receptacle that will not reset, trips repeatedly, or fails its test should not be treated as protective. Disconnect the affected circuit and have the wiring and appliance loads checked. Do not assume that a self-test feature eliminates the need for manual checks or makes an incorrectly wired installation safe.

Frequently Asked Questions

Can I replace a 20A RV GFCI with a 15A outlet?

Only use a receptacle that is compatible with the branch circuit and its overcurrent protection. The RV Designer option is specified for 15A or 20A protected circuits, while the other RV-suitable options here are 15A; confirm compatibility before installing.

How do I know if an RV GFCI is wired correctly?

With the receptacle installed, use its TEST control and confirm that power is interrupted, then press RESET and confirm power returns. Also check any downstream outlets intended to be protected; call a qualified technician if the test fails or wiring is uncertain.

Does an RV GFCI outlet need a ground wire?

GFCI operation detects current imbalance, but that does not make an ungrounded installation equivalent to a properly grounded circuit. The S807 is specified for grounded two-wire branch circuits; have an RV electrician assess any missing or questionable ground before replacement.

How often should I test an RV GFCI outlet?

A common safety practice is to test a GFCI monthly using its TEST and RESET controls. Test it after replacement as well, and stop using the circuit if the device will not trip or reset.

Can one RV GFCI protect other outlets?

Yes, a GFCI wired with downstream receptacles on its LOAD terminals can protect those outlets too. Wiring downstream protection incorrectly can leave outlets unprotected, so identify the LINE and LOAD conductors and verify each intended outlet after installation.